Horizontal
Cross-Flow Wet Scrubber
CF
Guaranteed control for
HCl, HNO3,
HF, H2SO4,
Cl2,
H2S,
NH3,
and others. |
|
see also: specifications
| color drawing |
Cross
Flow Scrubber Specification
Cross flow scrubber shall be
comprised of one or two stages, each having elements that are suited
to the function that it performs. The first stage removes the bulk of
the contaminant from the air stream. It may be continuously wetted to
prevent plugging. The second stage is a mist eliminator.
In a wet scrubber, water or scrubbing
liquid is the media which removes pollutants from the air. When the
water is recirculated, addition of fresh water is necessary to purge
contaminants that accumulate and to replace evaporation losses. Fresh
water may be added to the recycle reservoir either continuously or on
a periodic basis.
Scrubbers are frequently used in
applications where the air stream is being treated to remove acid
fumes. Strong alkali is often added to the recycled scrubbing solution
in order to neutralize the acids and maintain a neutral pH. The
addition of chemical may be controlled manually, or automatically by a
pH controller.
The Fume scrubbers can be fabricated
from homogenous, virgin-grade, UV-resistant polypropylene homopolymer,
or PVC using hot gas welding methods, Mild Steel, 304 Stainless Steel,
316 Stainless Steel. All units are hydrostatically tested at the
factory. The maximum temperature rating for polypropylene units is 180
degrees Fahrenheit and 140 degrees for PVC.
Bolted access ports are provided for
inspection of the interior packing and mist eliminator elements.
Gasket made from closed cell PVC foam is provided. Hardware is 316
S.S. maximum bolt torque 10#.
1. Intent
This Specification defines the design
requirements, the quality and types of workmanship and materials, and
the performance standards and guarantees for equipment, materials and
services supplied by Tri-Mer Corporation.
2. Scope
The vendor (Tri-Mer Corporation)
shall furnish wet scrubbers complete with auxiliaries and options
described herein. The system shall include but is not limited to the
following:
- All scrubber internals necessary to
provide adequate process capture and to achieve the designed
performance.
- Mist eliminator to achieve entrained liquid separation.
- Flanged connections for all external water fill, water makeup and
drain piping as required and optioned.
- Controls if optioned, to automatically feed make-up water, control
liquid level, monitor pressure.
- Fan if optioned.
- Complete shop coating of required areas with Tri-Mer Coat or
resistant paint for external surfaces.
- Self contained recirculation system or remote recycle tank.
- Full turnkey systems.
3. Design Requirements
- The Wet Scrubbers shell
shall be manufactured of Polypropylene, Polyvinylchloride, (PVC)
Stainless steel or Mild steel. Vendor shall evaluate materials and
select the most appropriate material for this service.
- The Wet Scrubber shell shall be provided with access ports /
doors to allow limited access to the internals of the unit. The
Scrubber shell shall be equipped with flanged pipe connections or
female NPT connections for the introduction of makeup and drain water
as well as various types of level control, pH fittings, and
recirculation liquid connections.
- The Wet Scrubbers shall be equipped with random dumped
Jaeger Tri Pack packing. The depth of the packing shall be determined
per application by TRI-MER Corp.
- The Wet Scrubber shall be equipped with a high efficiency
(95% @ 15 micron and larger) mist eliminator of the chevron blade type
of a coalescing type mesh pad. (99% @ 10 micron and larger mist)
Material of construction for the mist eliminator shall be PVC
(Polypropylene, Stainless Steel also available).
- The fan, if optioned, shall be manufactured from (FRP,
PVC/PP with coated steel impeller, Stainless Steel), or a material
which is equally suitable for this environment.
- The fan and motor shall be designed for system static
pressure will per application depending on packing depth and mist
eliminator selection. Pressure drop calculations through the Scrubber
plus
External delta P for the customers ductwork losses.
- The sound levels generated by the Vendor furnished equipment
during normal operation shall not exceed 85 dBA-weighted, slow
response, under free field condition, at a horizontal distance of 10
feet from the surface of sound generation. The Vendor as optioned
shall furnish silencers.
- Vendor shall provide electric motor drives for each fan.
Vendor shall be responsible for the selection of the motor
characteristics and the motor mounting.
- All electrical equipment provided by the vendor shall be
supplied in NEMA rated type enclosures.
- All equipment manufactured by Tri-Mer Corporation is
warranted under the standard Tri-Mer Corporation one-year warranty.
All purchased components are warranted under the respective
manufacturer warranty.
4. Standard
Supplied Components
Standard Purchased components
furnished on the Tri-Mer Corporation Wet Scrubbers are as follows:
- Dwyer Magnehelic
differential pressure gage for monitoring pressure drop.
- Hayward or equal manual valves for water fill.
- ASCO or equal electrically actuated solenoid valves for auto
water fill.
- Dwyer fresh water make-up flow meter.
- ANSI or equal recirculation pump.
- Signet or equal recirculation liquid flow meter.
- Schedule 80 PVC plumbing.
- Vinyl tubing with traps for differential pressure
connections.
- Fan. (See Options, below)
5. Components
Supplied by Others
- Tie downs, guy wires,
anchor bolts and foundations.
- Field assembly.
- Field wiring.
- Fresh water and drain piping to supplied 150# flanges.
- Mating flanges to customer connections, hardware and
gaskets.
- Interconnecting duct. (See Options, below)
- Heat tracing and insulation.
- Remote chemical storage.
6. Options:
Electrical Control Panel: An electrical
starter and control panel with NEMA 12 enclosure and fused main and
disconnect switch. Designed for 460 volt / 3-phase - 60 hertz
electrical supply. Internal components of the control panel shall be
pre-wired and terminal blocks shall be provided
for connection of external control.
PH Control: To consist of pH sensor, analyzer, chemical
metering pump. Components may be factory installed or shipped loose
for remote customer location.
Automatic Liquid Level Control: To consist of level sensors,
and water make-up solenoid valve.
High and Low Level Alarms: To consist of level sensors and
controls in optioned control panel.
Exhaust Blower: To be constructed of Polypropylene, PVC, FRP,
Mild Steel, & Stainless Steel.
PLC Interface:
Send me
more information about
Wet Gas Scrubbers...
1 - 877 - 844 - 3293
Call toll free in the USA
|
IAS Dust Collectors
|
1-877-844-3293
|
Click
here to see our complete Product Line Card.
dust collectors |
mist collection systems |Fume Extractors
gas scrubbers | wet
collectors | HEPA
air cleaners
commercial
air cleaners |
new filters |
cleanroom filtration
about us | home | contact
us
IAS Dust Collectors
P.O. Box 90246
Raleigh, NC 27675
Phone: 919-844-3293 FAX:
919-518-1667
See also:
HEPA Vacuum Systems
by IAS Industrial Vacuums
Dust Collection Systems by
Industrial Air Solutions Global Replacement Air Filters for Furnace and Air Conditioner
Buy Air Filters Online for
Furnace, Air Conditioner, HVAC and More
Commercial Air Cleaners and Hospital Air Purification
©2008 all rights reserved
title: Wet Srubbers
|