Vertical Flow
Packed Tower Scrubber
The best
packed bed scrubber where gas steams have high loads. |
|
see also: specifications
| color drawing |
Vertical Flow
Scrubber Specification
They consist of one or two
stages, each having elements that are suited to the function that it
performs. The first stage removes the bulk of the contaminant from
the air stream. It may be continuously wetted to prevent plugging.
The second stage is a mist eliminator.
In a wet scrubber, water or
scrubbing liquid is the media which removes pollutants from the air.
When the water is recirculated, addition of fresh water is necessary
to purge contaminants that accumulate and to replace evaporation
losses. Fresh water may be added to the recycle reservoir either
continuously or on a periodic basis.
Scrubbers are frequently
used in applications where the air stream is being treated to remove
acid fumes. Strong alkali is often added to the recycled scrubbing
solution in order to neutralize the acids and maintain a neutral pH.
The addition of chemical may be controlled manually, or
automatically by a pH controller.
The Fume scrubbers can be
fabricated from homogenous, virgin-grade, UV-resistant polypropylene
homopolymer, or PVC using hot gas welding methods, Mild Steel, 304
Stainless Steel, 316 Stainless Steel. All units are hydrostatically
tested at the factory. The maximum temperature rating for
polypropylene units is 180 degrees Fahrenheit and 140 degrees for
PVC.
Bolted access ports are
provided for inspection of the interior packing and mist eliminator
elements. Gasket made from closed cell PVC foam is provided.
Hardware is 316 S.S. maximum bolt torque 10#.
1. Intent
This Specification defines
the design requirements, the quality and types of workmanship and
materials, and the performance standards and guarantees for
equipment, materials and services supplied by Tri-Mer Corporation.
2. Scope
The vendor (Tri-Mer
Corporation) shall furnish wet scrubbers complete with auxiliaries
and options described herein. The system shall include but is not
limited to the following:
- All scrubber internals
necessary to provide adequate process capture and to achieve the
designed performance.
- Mist eliminator to achieve entrained liquid separation.
- Flanged connections for all external water fill, water makeup and
drain piping as required and optioned.
- Controls if optioned, to automatically feed make-up water, control
liquid level, monitor pressure.
- Fan if optioned.
- Complete shop coating of required areas with Tri-Mer Coat or
resistant paint for external surfaces.
- Self contained recirculation system or remote recycle tank.
- Full turnkey systems.
3. Design
Requirements
- The Wet Scrubbers
shell shall be manufactured of Polypropylene, Polyvynilchloride,
(PVC) Stainless steel or Mild steel. Vendor shall evaluate materials
and select the most appropriate material for this service.
- The Wet Scrubber shell shall be provided with access ports
/ doors to allow limited access to the internals of the unit. The
Scrubber shell shall be equipped with flanged pipe connections or
female NPT connections for the introduction of makeup and drain
water as well as various types of level control, pH fittings, and
recirculation liquid connections.
- The Wet Scrubbers shall be equipped with random dumped
Jaeger Tri Pack packing. The depth of the packing shall be
determined per application by TRI-MER Corp.
- The Wet Scrubber shall be equipped with a high efficiency
(95% @ 15 micron and larger) mist eliminator of the chevron blade
type of a coalising type mesh pad. (99% @ 10 micron and larger mist)
Material of construction for the mist eliminator shall be PVC
(Polypropylene, Stainless Steel also available).
- The fan, if optioned, shall be manufactured from (FRP,
PVC/PP with coated steel impeller, Stainless Steel), or a material
which is equally suitable for this environment.
- The fan and motor shall be designed for system static
pressure will per application depending on packing depth and mist
eliminator selection. Pressure drop calculations through the
Scrubber plus
External delta P for the customers ductwork losses.
- The sound levels generated by the Vendor furnished
equipment during normal operation shall not exceed 85 dBA-weighted,
slow response, under free field condition, at a horizontal distance
of 10 feet from the surface of sound generation. The Vendor as
optioned shall furnish silencers.
- Vendor shall provide electric motor drives for each fan.
Vendor shall be responsible for the selection of the motor
characteristics and the motor mounting.
- All electrical equipment provided by the vendor shall be
supplied in NEMA rated type enclosures.
- All equipment manufactured by Tri-Mer Corporation is
warranted under the standard Tri-Mer Corporation one-year warranty.
All purchased components are warranted under the respective
manufacturer warranty.
4. Standard
Supplied Components
Standard Purchased components
furnished on the Tri-Mer Corporation Wet Scrubbers are as follows:
- Dwyer Magnehelic
differential pressure gage for monitoring pressure drop.
- Hayward or equal manual valves for water fill.
- ASCO or equal electrically actuated solenoid valves for auto
water fill.
- Dwyer fresh water make-up flow meter.
- ANSI or equal recirculation pump.
- Signet or equal recirculation liquid flow meter.
- Schedule 80 PVC plumbing.
- Vinyl tubing with traps for differential pressure
connections.
- Fan. (See Options, below)
5. Components
Supplied by Others
- Tie downs, guy wires,
anchor bolts and foundations.
- Field assembly.
- Field wiring.
- Fresh water and drain piping to supplied 150# flanges.
- Mating flanges to customer connections, hardware and
gaskets.
- Interconnecting duct. (See Options, below)
- Heat tracing and insulation.
- Remote chemical storage.
6. Options:
Electrical Control Panel: An electrical
starter and control panel with NEMA 12 enclosure and fused main and
disconnect switch. Designed for 460 volt / 3-phase - 60 hertz
electrical supply. Internal components of the control panel shall be
pre-wired and terminal blocks shall be provided
for connection of external control.
PH Control: To consist of pH sensor, analyzer, chemical
metering pump. Components may be factory installed or shipped loose
for remote customer location.
Automatic Liquid Level Control: To consist of level sensors,
and water make-up solenoid valve.
High and Low Level Alarms: To consist of level sensors and
controls in optioned control panel.
Exhaust Blower: To be constructed of Polypropylene, PVC, FRP,
Mild Steel, & Stainless Steel.
PLC Interface:
Let's Discuss it!
1 - 877 - 844 - 3293
Call toll free in the USA
Send me
more information about
Vertical Flow Packed Tower Scrubbers...
1 - 877 - 844 - 3293
Call toll free in the USA
|
IAS Dust Collectors
|
1-877-844-3293
|
Click
here to see our complete Product Line Card.
dust collectors |
mist collection systems |Fume Extractors
gas scrubbers | wet
collectors | HEPA
air cleaners
commercial
air cleaners |
new filters |
cleanroom filtration
about us | home | contact
us
IAS Dust Collectors
P.O. Box 90246
Raleigh, NC 27675
Phone: 919-844-3293 FAX:
919-518-1667
See also:
HEPA Vacuum Systems
by IAS Industrial Vacuums
Dust Collection Systems by
Industrial Air Solutions Global Replacement Air Filters for Furnace and Air Conditioner
Buy Air Filters Online for
Furnace, Air Conditioner, HVAC and More
Commercial Air Cleaners and Hospital Air Purification